Abstract:
During the battery production,the wastewater would drain with some heavy metal pollutants and organic pollutants like Hg,Zn,Mn,COD and BOD.By this EWP unit test,we want to research if we can use Zn(OH)
2 flocculate caused by influent wastewater as adsorption layer bed to purify the water while adjusting the pH value to 7.5~8.5.By using the EWP unit,Hg can be reduced into 0.000 92 mg/L with the removing rate of 96.2%;Zn removing rate is 99.1%;Mn removing rate is 55.1%;COD removing rate is 19.6%;BOD removing rate is 28.3%.